Iolmaster 500 pdf files

What is the value of swept source oct technology in biometry. Usb flash drive for iolmaster 500 and iolmaster 700 download here. The zeiss iolmaster 500 includes the haigisl formula which is dedicated to myopic and hyperopic postlvc cases and is very convenient as it requires no clinical history data. The new iolmaster 700 biometry next generation biometry. Technical data iolmaster 500 experience the essence of non. Jan 12, 20 in case of failure to measure axial length by iolmaster 500, the axial length can be obtained by ultrasound, and then transferred to iolmaster 500 for the iol power calculation. The iolmaster 500 stands on a long heritage of highly precise measurement data. Designed for robustness, reliability and exceptional system integrity,the iolmaster 500 offers a wide range of builtin iol power calculation options, including the latest haigis and holladay 2 formulas.

It also includes the reference image functionality for use in the zeiss cataract suite markerless workflow. What should i bear in mind for taking the measurements. From there, data can be exported to other file formats. The device can be linked to the callisto eye and the ompi lumera microscope through zeiss forum software. The iolmaster is a combined biometry device for measurements on the. London carl zeiss meditec presented the companys new iolmaster 700 with sweptsource biometry here. Patient date of birth gender patient id smith carol 1201955 female 151769901 doctor john doeoperator iolmaster 700 version 1. For al values, the iolmaster 700, iolmaster 500, and ascan measurements showed excellent agreement all icc 0. If the lens power calculation is based on iolmaster measurements, only lens constants optimized for use with the zeiss iolmaster should be applied.

Position instrument table, headrest and instrument properly to avoid tensed up patients and unnecessary eye movements. The iolmaster 700 is a core component of the zeiss cataract suite marker. The iolmaster 700 is a new biometry device providing the same basic measuring features as the iolmaster 500 and in addition, measures central corneal thickness and lens thickness. Iolmaster 700 is as precise as iolmaster 500 in getting biometric information.

Interobserver agreement between the two practitioners was found to be good for each parameter measured by the aladdin. Iolmaster keratometry for the calculation of toric intraocular lens power and orientation wilfried bissmann, phd1, marcus blum, md 2, kathleen s. Talking about workflow efficiency, it is important that the devices used for surgery work well together. The iolmaster may only be connected to private networks which are protected from public networks internet by firewalls conforming to the latest technical standards. Optimized lens constants for the calculation of intraocular lens power with the zeiss iolmaster are published by the user group for laser interference biometry ulib on its website.

Proven in the field for more than a decade, the iol master partial coherence interferometry pci technology is the acknowledged reference point in biometry today. Pdf purpose to compare the measurements and failure rates. The iolmaster500 is the gold standard in optical biometry with more than 100 million successful iol power calculations to date. Iolmaster 500 surgeons clear preference in biometry. Always keep this user manual and all accompanying documents in the immediate. Sep 14, 2014 london carl zeiss meditec presented the companys new iolmaster 700 with sweptsource biometry here.

Iolmaster cannot currently be directly interfaced with compulink advantage software and are not supported by compulink customer care. Furthermore, the population means for cataract eyes for axial length, anterior chamber depth and corneal radii from the iolmaster 700 and. Agreement of iol power and axial length obtained by iolmaster. Iol master 500 is intended for biometric determination of ocular measurements of axial length, anterior chamber depth, corneal radius, whiteto white wtw, and for the measurement of pupil size and. For al values, the iolmaster 700, iolmaster 500, and ascan. The iolmaster model 700 the first swept source octbased biometer and enables oct imaging. The iolmaster keratometry offers less technician dependence and version 5 and 500 eliminates many of the prior versions focusing issues. The new zeiss iolmaster 700 with swept source biometry zeiss was the inventor of the first optical biometer and pioneered the introduction of oct for ophthalmology. When positioning the instrument to the patient overview menu, a coarse focus will do. Both reference images and keratometry data are transferred to zeiss callisto eye computer assisted surgery system. Zeiss iolmaster medical optical biometer for optometry cataract detection. Pdf evaluation and comparison of the new swept source oct. The zeiss iolmaster 500 is the gold standard in optical biometry with more than 100.

Zeiss presents the new iolmaster 700 for better predictability and optimized workflows in cataract surgery the iolmaster 700 with swept source biometry enables physicians to identify irregular geometries of their patients eyes at an early stage. To study the refractive outcome of cataract surgery employing iolmaster biometry data and to compare it with that of applanation ultrasonography in a prospective study of 100 eyes that underwent phacoemulsification with intraocular lens implantation. Transfer of iolmaster patient measurements to the holladay. A complete workstation for lowhassle biometry and highconfidence iol selection, the iolmaster 500 incorporates advancements designed with.

Patients qualified to continue had biometric measurements with the study device iolmaster 700 and the comparative devices iolmaster 500 and lenstar ls 900. Czm may provide guidance on a besteffort basis but is not responsible for the setup and administration of a users office network. The device allows for optimized workflows in cataract surgery, according to experts at a. In case of failure to measure axial length by iolmaster 500, the axial length can be obtained by ultrasound, and then transferred to iolmaster 500 for the iol power calculation. Todays leading formula holladay 2 has now been added directly to the iolmaster 500 device carl zeiss meditec ag. Iolmaster 500 for two typical sets of constants each a and b have been. Al measurements were not possible for 17 eyes with iolmaster 500. The iolmaster keratometry can be delegated to several trained staff members with virtually no interoperator difference in measurement accuracy. In 47 eyes, al measurements used and from both tools were obtained in comparisons. Zeiss iol master 500 with table printer medit equip. This study aims to compare the results and evaluate the agreement between iol power and axial length obtained by iolmaster 500 and iolmaster 500 with sonolink connection. Czm may provide guidance on a besteffort basis but is not responsible for the. The iolmaster 500 application is dedicated to lowhassle biometry and highconfidence iol selection. The iolmaster 500 is the benchmark for precision biometry.

The zeiss iolmaster 500 is an integral part of the zeiss cataract suite. Designed for robustness, reliability and exceptional system integrity, the iolmaster 500 offers a wide range of builtin iol power calculation options, including the latest haigis and holladay 2 formulas. With the iolmaster 500 from zeiss doctors get a reliable, fast and easytouse optical biometer for measurements they can depend on. The use of advanced formulas to improve the accuracy of cataract surgery has been a process of ongoing improvement since the 1980s. Third party products are cited for information purposes only and this does not represent approval or recommendation of these products. With the new version of the zeiss iolmaster 500, you get a piece of cuttingedge technology that points the way to the future of optical biometry. Apr 09 2020 iolmaster500manual 23 pdf drive search and download pdf files for free. Zeiss clarus 500 instructions for use manual pdf download. The iolmaster 500 application logs extensive information about the dicom operations to its log file. The zeiss iolmaster 500 is the gold standard in optical biometry with more than 100 million successful iol power. Pdf purpose to evaluate the results of optical biometry using the iolmaster 500, lenstar ls 900 and aladdin in eyes with cataract. Errors associated with iolmaster biometry as a function of. There was no statistically significant difference in predicted iol powers between the aladdin and the iolmaster.

Pdf iolmaster 500 and integration of the holladay 2 formula for. Each study site had 1 unit of ssoct biometry, 1 unit of pci biometry, and 1 unit of olcr biometry. The ultrasound testing also performed at the office is very accurate and is covered by ohip. Figure 1, enables oct imaging and visualization across the entire length of the eye. All patients were included in the study unless they were under 18 years of age or if they had a diagnosis of iolmaster 500. Manual marking steps can be skipped altogether for efficient 8 and more precise 7 toric iol alignment with reduced residual astigmatism. Comparison of ocular biometry using new sweptsource optical. Please let dr hillson know if you are interested in having iolmaster testing to help with your cataract surgery or if you would like more information to help with your decision. Iolmaster 500 and integration of the holladay 2 formula for. The moment iol power calculation becomes second nature. The newest iteration uses sweptsource oct to visualize the full length of the eye, enabling the detection of unusual ocular geometry and crystalline lens tilt to assist with predicting the effective lens position. Zeiss presents new iolmaster 700 with sweptsource biometry.

Iolmaster testing is an option available for patients who would like the best possible accuracy and the latest and best technology. Agreement of iol power and axial length obtained by. Kunert, md the deviation between the maximum and minimum axial values for astigmatisms from 0. The iolmaster 500 simplifies iol power calculation for patients with.

It enables robust and repeatable measurements and shows excellent agreement with manual keratometry while achieving higher. However, the manufacturer may be able to assist you in networking the devices and configuring it to export the image files for manual import. Iolmaster 500 and integration of the holladay 2 formula for intraocular lens. Thus, the intraocular lens or iol sits more or le ss in the same position the natural lens once occupied.

The zeiss iol master 500 is the gold standard in optical biometry with more than 100 million successful iol power calculations to date. Improving upon the gold standard in biometry for cataract surgery 8 shareef mahdavi sm2 strategic pleasanton, ca 7 0 100 200. Penetration ability was also compared between the two devices. Zeiss iolmaster 500 trusting the experience of 100 million iol power calculations. Iolmaster 500 was not able to quantify 8 of the 55 eyes with posterior subcapsular cataracts locs iii psc grade.

Wolfgang haigis, university eye clinic, wuerzburg, germany, carl zeiss meditec ag provides these iol constants in a downloadable file for importing into the zeiss iolmaster using the following media. Apr 09 2020 iol master 500 manual 23 pdf drive search and download pdf files for free. Apr 07, 2017 iolmaster 700 with the iolmaster 700, carl zeiss meditec ag did more than update the popular iolmaster 500. The iolmaster is a combined biometry device for measurements on the human eye. Use of zeiss iolmaster 500 patient data 1s88 opmi lumera t, opmi lumera i, s7 opmi lumera 2 from zeiss iolmaster 500 with toric option. Repeatability and agreement in optical biometry of a new. The dual mode facilitates measurements of axial length and keratometry without the need for manual interaction minimizing chairtime. Iolmaster keratometry for the calculation of toric. Page 1 of 7 z e i s s t e m p l a t e v e r s i o n 0. The iolmaster 700, the entry point to the zeiss cataract suite, is a new technology that combines optical biometry with sweptsource oct, allowing clinicians to image and measure the entire length of the eye.

Iolmaster testing is considered nonessential and is not covered by ohip. Technical data callisto eye from zeiss perfect integration for a streamlined workflow alternatively zeiss callisto eye can be mounted directly to the. Iol master 500 is intended for biometric determination of ocular measurements of axial length, anterior chamber depth, corneal radius, whiteto white wtw, and for the measurement of pupil size and deviation of the visual axis from the center of the pupil. Iolmaster 700 with the iolmaster 700, carl zeiss meditec ag did more than update the popular iolmaster 500. The iolmaster 500 ae supports several dicom services as service class user such as verification, encapsulated pdf, ophthalmic photography 8bit image storage and multiframe true color secondary capture image storage. By oliver findl, md, mba, febo i ntroduction of the first swept source octbased biometer, the iolmaster 700 carl zeiss meditec. Today, selecting the right iol to meet individual patient expectations is more crucial than ever. Comparison of a new sweptsource optical biometer with a partial. Only 1 eye of each patient was designated as the study eye.

Click the button below to add the zeiss iol master 500 with table printer to your wish list. Zeiss iolmaster 500 biometry a scan my eye equipment. This will allow a much larger group of surgeons to access the latest formula and should improve both intraocular lens. Iolmaster 700 managed to obtain al measurements in most eyes.

S c the iolmaster 700 the iolmaster 700 better predictability and optimized workflow compared with other biometers. Precision simplicity outcomes enter the iolmaster 500. In addition to optical biometry, it also offers oct imaging across the entire length of the eye. Iolmaster 500 optical biometry zeiss medical technology.

Zeiss iolmaster 500 trusting the experience of 100 million iol. Zeiss iol master 500 discover speedy biometry the iolmaster 500 with holladay 2 more information. With the new version of the iolmaster 500, you get a piece of cuttingedge technology that points the way to the future of optical biometry. Always keep this user manual and all accompanying documents in the immediate vicinity of. Mastery is achieved through constant refinement the iolmaster 500 is dedicated to lowhass. A reference image is acquired and used for intraoperative matching with the live eye image during cataract surgery.

598 1210 419 838 168 1071 328 1300 767 154 449 1430 724 1613 1125 1553 145 661 1257 10 35 1446 1500 1257 958 903 621 1357 723 987 1048 1030 1108 167 505 1043 218 274 964 1219 1080 1375 499